Samsung Premium Heat Pump, FJM Series, 208-230 V, 6.2 A, 125 W, 60 Hz, 1 ph Phase, 20000 Btu/hr, 3320 cfm, 15 EER Rating, 23 SEER, 10.5 HSPF, 1.2 A Fan Rating, Flared Connection, Inverter Compressor, R-32 Refrigerant, Tonnage: 1.75 ton, 1/4 in Liquid Line, 3/8 in Suction Line, Vent, Ducted or Ductless: Ductless, 51 dBA Sound Level, Steel, Finish: Galvanized/Powder-Coated, 14 to 115 deg F, 47-5/8 in H x 37 in W x 13 in D
Amperage Rating6.2 A
BTU Rating20000 Btu/hr
CFM Rating3320 cfm
Compressor TypeInverter
Connection TypeFlared
Dimensions47-5/8 in H x 37 in W x 13 in D
EER Rating15
Fan Rating1.2 A
FinishGalvanized/Powder-Coated
Frequency Rating60 Hz
HSPF Rating10.5
Liquid Line Size1/4 in
MaterialSteel
Phase1 ph
Power Rating125 W
Refrigerant TypeR-32
SEER Rating23
SeriesFJM Series
Sound Level51 dBA
Suction Line Size3/8 in
Temperature Rating14 to 115 deg F
Tonnage1.75 ton
Vent, Ducted or DuctlessDuctless
Voltage Rating208-230 V
The system shall provide high heating capacity at -13°F (-25°C) outside temperature and 100% rated heating capacity at 5°F (-15°C) outside temperature
The outdoor unit shall have a base pan heater as standard for optimal defrost cycle water drainage
Auto-restart after power loss
Available maximum current setting option to reduce operating current
System energy consumption can be viewed using the Samsung SmartThings mobile app (not revenue grade, for reference only)
Soft-start to reduce current demand during compressor start
The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire Construction
The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger
The heat exchanger shall be mechanically bonded fin to copper tube Refrigerant System
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by electronic expansion valves at the outdoor unit
The system shall include an R32 alarm output plug on indoor units with refrigerant leak detectors and outdoor unit for notification of R32 leak detection when refrigerant leak detectors are installed and configured (MIM-B14U accessories are required).