Samsung Hylex™ Inverter Driven Heat Pump Condensing Unit, 208 to 230 V, 24.1 A, 125 W Power, 60 Hz Frequency, 1 ph, Number of Fan Speeds: 3, Heating BTU Rating: 7500 to 35000 Btu/hr, Cooling BTU Rating: 11000 to 30000 Btu/hr, Heating CFM Rating: 2684 cfm, Cooling CFM Rating: 2684 cfm, 11 EER, 18 SEER, 10 HSPF, Twin BLDC Rotary Compressor, R-410A Refrigerant, 3/8 in Liquid Line, 5/8 to 7/8 in Suction Line, 30 A Fuse, Inverter Drive, Heating Sound Level: 52 dB, Cooling Sound Level: 50 dB, Steel, Baked-On Powder-Coated/Galvanized, Heating Operating Temperature: -13 to 75 deg F, Cooling Operating Temperature: 23 to 125 deg F, 37 in Overall Width, 39-5/16 in Overall Height, Additional Information: 13 in D
Additional Information13 in D
Amperage Rating24.1 A
Compressor TypeTwin BLDC Rotary
Cooling BTU Rating11000 to 30000 Btu/hr
Cooling CFM Rating2684 cfm
Cooling Operating Temperature23 to 125 deg F
Cooling Sound Level50 dB
Drive TypeInverter
EER Rating11
FinishBaked-On Powder-Coated/Galvanized
Frequency Rating60 Hz
Fuse Rating30 A
HSPF Rating10
Heating BTU Rating7500 to 35000 Btu/hr
Heating CFM Rating2684 cfm
Heating Operating Temperature-13 to 75 deg F
Heating Sound Level52 dB
Liquid Line Size3/8 in
MaterialSteel
Number of Fan Speeds3
Overall Height39-5/16 in
Overall Width37 in
Phase1 ph
Power Rating125 W
Refrigerant TypeR-410A
SEER Rating18
Suction Line Size5/8 to 7/8 in
Voltage Rating208 to 230 V
Inverter driven heat pump condensing unit compatible with air handling units and A coils with a thermostatic expansion valve
100% rated heating capacity at 5 deg F outside temperature (refer to capacity tables in outdoor unit technical data book for full capacity details)
Soft start compressor minimizing current inrush
Base pan heater equipped as standard
The condensing unit heat exchanger salt spray test method ISO 9227
The heat exchanger showed no unusual rust or corrosion development to 3000 hr
The system (outdoor unit with MXD-U000XN AHU control unit) shall provide three-fan speed control of the indoor unit increasing performance and dehumidification
Refrigerant pipe connections and service ports are located inside the heat pump cabinet
Refrigerant pipes can enter the cabinet on the front, side, back or bottom
Requires MXD-U000XN AHU control unit (purchased separately) installed near the indoor unit for operation
Control wiring shall be 2 x 18 AWG
Compatible with standard 24 V thermostats
Requires B reversing valve signal (24 V energized for heating)
The compressor shall be hermetically sealed, inverter controlled, BLDC rotary
The outdoor unit heat exchanger shall be mechanically bonded aluminum fin to copper tube
Uses traditional unitary line sets (liquid pipe does not require insulation)