Samsung Single Zone Heat Pump Split System Outdoor Unit, Duct S Series, 208 to 230 V, 22.9 A, 244 W, 60 Hz, 1 ph, 34000 Btu/hr Heating, 30000 Btu/hr Cooling, 1130 cfm Heating CFM Rating, 1130 cfm Cooling CFM Rating, 11 EER Rating, 19 SEER, 9 HSPF, Pipe Connection, Inverter Driven, Twin BLDC Rotary Compressor, R-32 Refrigerant, 50 dB Heating Sound Level, 52 dB Cooling Sound Level, Steel, Finish: Galvanized/Powder-Coated, -4 to 75 deg F Heating Operating Temperature, 0 to 122 deg F Cooling Operating Temperature, 37 in Overall Length, 13 in Overall Width, 39-5/16 in Overall Height
Amperage Rating22.9 A
Compressor TypeInverter Driven, Twin BLDC Rotary
Connection TypePipe
Cooling BTU Rating30000 Btu/hr
Cooling CFM Rating1130 cfm
Cooling Operating Temperature0 to 122 deg F
Cooling Sound Level52 dB
EER Rating11
FinishGalvanized/Powder-Coated
Frequency Rating60 Hz
HSPF Rating9
Heating BTU Rating34000 Btu/hr
Heating CFM Rating1130 cfm
Heating Operating Temperature-4 to 75 deg F
Heating Sound Level50 dB
MaterialSteel
Overall Height39-5/16 in
Overall Length37 in
Overall Width13 in
Phase1 ph
Power Rating244 W
Refrigerant TypeR-32
SEER Rating19
SeriesDuct S Series
Voltage Rating208 to 230 V
The indoor unit shall have an integral condensate pump with maximum 29" lift from bottom of the unit with check valve and float switch that disables indoor in the event of condensate overflow.
The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort.
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app.
Auto-restart after power loss
Soft-start compressor minimizing current inrush
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable.
Outdoor unit: Galvanized steel with a baked-on powder coated finish for durability.
Indoor unit: Insulated, galvanized steel.
All heat exchangers shall be mechanically bonded aluminum fin to copper tube.
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire.
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit.
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required).
Smart pressure control feature that adjusts fan speed based on ESP delivering consistent heating and cooling power
The indoor unit shall have a smart-tuning function that can provide optimized comfort by allowing the occupant to offset the fan CFM curve to increase or decrease airflow.
The indoor unit shall have automatic air volume scanning for simple setup and optimized comfort settings for the occupant
Control wiring shall be 2 X 16 AWG wire.
No additional interface modules/adapters are required when connecting to Samsung central control options.
The unit shall be operated via a wireless or wired remote control with DDC type signal.
Dual set temperature support when connected to supported controllers.