Samsung 4-Way Mini Cassette Indoor Unit, 208 to 230 V, 0.3 A, 2.35 kW Cooling, 3.6 kW Heating, 60 Hz, 1 ph, 3 Fan Speeds, 17000 Btu/hr Cooling, 20000 Btu/hr Heating, 300 to 371 cfm, 3.66 EER Rating, 20.5 SEER, 9.5 HSPF, Connection Type: Flared, 1/2 x 1/4 in Connection, R-32 Refrigerant, Tonnage: 1.42 ton, 39 dBA Sound Level, HIPS/Polypropylene, 64 to 90 deg F Cooling, 86 deg F Heating, 22-5/8 in Overall Length, 22-5/8 in Overall Width, 9-13/16 in Overall Height, For Use With: Multi-Zone Systems, Additional Information: 1/2 in Gas Pipe Size, 1/4 in Liquid Pipe Size, 24-3/8 in L x 24-3/8 in W x 2-3/8 in H Fascia Panel
Additional Information1/2 in Gas Pipe Size, 1/4 in Liquid Pipe Size, 24-3/8 in L x 2 more...1/2 in Gas Pipe Size, 1/4 in Liquid Pipe Size, 24-3/8 in L x 24-3/8 in W x 2-3/8 in H Fascia Panel less
Temperature Rating64 to 90 deg F Cooling, 86 deg F Heating
Tonnage1.42 ton
Voltage Rating208 to 230 V
The indoor unit shall feature WindFree™ mode. When activated in cooling mode, the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit, preventing cold air drafts on occupants
The indoor unit shall have an integral condensate pump with maximum 29" lift from bottom of the unit with check valve and float switch to disable unit in the event of condensate overflow
The indoor unit fascia panel shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
Interconnecting control wiring between the outdoor to indoor shall be 2-conductor/stranded copper/shielded cable between 18-16 AWG
Insulated, HIPS chassis and fascia panel certified to UL94 V0
The indoor unit shall include a knock-out for outside air capability (booster fan connection)
The heat exchanger shall be mechanically boded aluminum fin to copper tube
Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the indoor unit refrigerant leak detector detects a refrigerant leak (MIM-B14U accessory is required)
Three fan speed settings and auto settings
Washable filter as standard
Fascia panel shall have LED display, infrared receiver, and motorized louvers
The WindFree™ function will close the supply air outlet louver while in cooling mode to gently disperse cool air into the space without blowing directly onto occupants
The WindFree™ feature is optional and can be enabled using central or local control options
The unit shall be operated via a wireless or wired remote control with DDCtype signal (purchased separately)
Dual set temperature support when connected to supported controllers
External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat (MIM-B14U accessory required)
External heat control configuration settings includes outside ambient external heat lockout, outside ambient compressor lockout, and time delay options (MIMB14U accessory required)
Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating (MIM-B14U accessory required)