Samsung Split System Heat Pump, Model: AR12DXDA, 208-230 V, 12 A, 60 Hz, 1 ph Phase, 3 Fan Speeds, 24000 Btu/hr Heating, 12000 Btu/hr Cooling, 463 cfm Heating CFM Rating, 427 cfm Cooling CFM Rating, 14.1 EER Rating, 24 SEER, 10.5 HSPF, Connection Type: Flared, 1/4 in Liquid Line, 3/8 in Suction Line, 20 A Fuse Rating, 46 dBA Heating Sound Level, Wall Mounting, HIPS, -5 to 75 deg F Heating Operating Temperature, 14 to 115 deg F Cooling Operating Temperature, 31-1/8 in Overall Length, 11-1/4 in Overall Width, 21-9/16 in Overall Height
Amperage Rating12 A
Connection TypeFlared
Cooling BTU Rating12000 Btu/hr
Cooling CFM Rating427 cfm
Cooling Operating Temperature14 to 115 deg F
EER Rating14.1
Frequency Rating60 Hz
Fuse Rating20 A
HSPF Rating10.5
Heating BTU Rating24000 Btu/hr
Heating CFM Rating463 cfm
Heating Operating Temperature-5 to 75 deg F
Heating Sound Level46 dBA
Liquid Line Size1/4 in
MaterialHIPS
ModelAR12DXDA
Mounting TypeWall
Number of Fan Speeds3
Overall Height21-9/16 in
Overall Length31-1/8 in
Overall Width11-1/4 in
Phase1 ph
SEER Rating24
Suction Line Size3/8 in
Voltage Rating208-230 V
The indoor unit shall feature WindFree™* mode. When activated in cooling mode the unit will close its louver and will disperse air into the space through thousands of micro-holes on the front of the indoor unit preventing cold air drafts on occupants.
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app.
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable.
Interconnecting control wiring between the outdoor to indoor shall be 2-conductor/stranded copper/shielded cable between 18-16 AWG.
Built-in motion sensor for airflow direction control and energy saving operation.
Indoor unit chassis shall be UL94 V0 with a galvanized steel mounting bracket
The indoor unit shall have easy access to wire, pipe, and drain connections via the access panel on the bottom of the unit for simple installation and service
The outdoor unit shall be galvanized steel with a baked-on powder coated finish for durability
The heat exchangers shall be mechanically bonded fin to copper tube
The system shall utilize low-GWP R-32 refrigerant
The compressor shall be hermetically sealed, inverter controlled, twin BLDC Rotary
Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
The indoor fan shall be a single cross-flow type
Three fan speed settings and auto settings
Automatic (motorized) vertical swing (up/down) and horizontal swing (left/right) louvers
The indoor unit shall ship with a rechargeable, solar-cell wireless controller. The wireless controller battery shall be charged with a USB C cable or the integral solar panel.
The included wireless controller shall have a pixel display that is visible in low light conditions.
Dual set temperature support when connected to supported wired controllers.
The indoor unit shall include an integral humidity sensor for improved humidity control functions.
The indoor unit shall have a simple connection for condensate overflow detection devices or any normally closed contact for simple unit shutdown.