Samsung Heat Pump Outdoor Unit, Duct S Series, 208 to 230 V, 13.2 A Cooling, 19.8 A Heating, 153 W, 60 Hz, 1 ph, 3 Fan Speeds, 27000 Btu/hr Heating, 24000 Btu/hr Cooling, 607 to 841 cfm Heating CFM Rating, 607 to 841 cfm Cooling CFM Rating, 11 EER Rating, 17.5 SEER, 8.7 HSPF, Connection Type: Flared, 1/4 in Liquid Line, 5/8 in Suction Line, 25 A Fuse Rating, Inverter Drive, 52 dBA Heating Sound Level, 50 dBA Cooling Sound Level, Steel, Galvanized/Powder-Coated, -4 to 75 deg F Heating Operating Temperature, 23 to 122 deg F Cooling Operating Temperature, 12-3/16 in Overall Length, 34-5/8 in Overall Width, 31-3/8 in Overall Height, Additional Information: R-32 Refrigerant Type
Additional InformationR-32 Refrigerant Type
Amperage Rating13.2 A Cooling, 19.8 A Heating
Compressor TypeInverter Driven, Twin BLDC Rotary
Connection TypeFlared
Cooling BTU Rating24000 Btu/hr
Cooling CFM Rating607 to 841 cfm
Cooling Operating Temperature23 to 122 deg F
Cooling Sound Level50 dBA
Correct Item GroupMulti Zone Outdoor Units
Drive TypeInverter
EER Rating11
FinishGalvanized/Powder-Coated
Frequency Rating60 Hz
Fuse Rating25 A
HSPF Rating8.7
Heating BTU Rating27000 Btu/hr
Heating CFM Rating607 to 841 cfm
Heating Operating Temperature-4 to 75 deg F
Heating Sound Level52 dBA
Liquid Line Size1/4 in
MaterialSteel
Number of Fan Speeds3
Overall Height31-3/8 in
Overall Length12-3/16 in
Overall Width34-5/8 in
Phase1 ph
Power Rating153 W
Refrigerant TypeR-32
SEER Rating17.5
SeriesDuct S Series
Suction Line Size5/8 in
Voltage Rating208 to 230 V
The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
Auto-restart after power loss
Soft-start compressor minimizing current inrush
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
Interconnecting control wiring between the outdoor to indoor shall be 2-conductor/stranded copper/shielded cable between 18-16 AWG
Outdoor unit: Galvanized steel with a baked-on powder-coated finish for durability
All heat exchangers shall be mechanically bonded aluminum fin to copper tube
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by an electronic expansion valve at the outdoor unit
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required)
Smart pressure control feature that adjusts fan speed based on ESP delivering consistent heating and cooling power
No additional interface modules/adapters are required when connecting to Samsung central control options
The unit shall be operated via a wireless or wired remote control with DDC type signal
Dual set temperature support when connected to supported controllers
Wired or wireless controllers must be purchased separately
External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat (MIM-B14U accessory required)
External heat control configuration settings includes outside ambient external heat lockout, outside ambient compressor lockout, and time delay options (MIMB14U accessory required)
Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating (MIM-B14U accessory required)