Samsung Single Zone Mini-Split Air Conditioner Condenser, 208-230 V, 9.7 A, 5.2 kW, 60 Hz, 1 ph, 18000 Btu/hr Cooling, 593 to 841 cfm Cooling CFM Rating, 12 EER Rating, 18.6 SEER, Flared Connection, 1/4 in Liquid Line, 1/2 in Suction Line, 15 A Fuse Rating, Inverter Drive, Tonnage: 1-1/2 ton, 58 dBA Cooling Sound Level, Steel, Galvanized, 23 to 122 deg F Cooling Operating Temperature, 34-5/8 in Overall Length, 25-1/8 in Overall Width, 12-3/16 in Overall Height, Brushless DC Motor, R-32 Refrigerant Type, Twin Rotary Compressor Type
Additional InformationBrushless DC Motor, R-32 Refrigerant Type, Twin Rotary Compres more...Brushless DC Motor, R-32 Refrigerant Type, Twin Rotary Compressor Type less
Amperage Rating9.7 A
Connection TypeFlared
Cooling BTU Rating18000 Btu/hr
Cooling CFM Rating593 to 841 cfm
Cooling Operating Temperature23 to 122 deg F
Cooling Sound Level58 dBA
Drive TypeInverter
EER Rating12
FinishGalvanized
Frequency Rating60 Hz
Fuse Rating15 A
Liquid Line Size1/4 in
MaterialSteel
Overall Height12-3/16 in
Overall Length34-5/8 in
Overall Width25-1/8 in
Phase1 ph
Power Rating5.2 kW
SEER Rating18.6
Suction Line Size1/2 in
Tonnage1-1/2 ton
Voltage Rating208-230 V
Low ambient cooling down to -40 deg F
The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
Auto-restart after power loss
Soft-start compressor minimizing current inrush
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable
Outdoor unit: Galvanized steel with a baked-on powder coated finish for durability
All heat exchangers shall be mechanically bonded aluminum fin to copper tube
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required)
Smart pressure control feature that adjusts fan speed based on ESP delivering consistent heating and cooling power
The indoor unit shall have automatic air volume scanning for simple setup and optimized comfort settings for the occupant
Control wiring shall be 2 X 16 AWG wire
No additional interface modules/adapters are required when connecting to Samsung central control options
The unit shall be operated via a wireless or wired remote control with DDC type signal
Wired or wireless controllers must be purchased separately
The outdoor unit shall have snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit
Night-time Quiet Mode: reduction of operational sound during evening hours (automatic or manual activation)