At only 7-7/8 in THK, the slim duct makes installation, maintenance and repair hassle-free. Its lightweight chassis also makes installation easier than ever. The slim duct unit includes a built-in condensate pump as standard.
Samsung Split System Unit, 208-230 V, 10.9 A, 84 W, 60 Hz, 1 ph, 3 Number of Fan Speeds, 12000 Btu/hr, 14000 Btu/hr, 300 cfm, 353 cfm, 399 cfm CFM Rating, 11.5 EER, 19 SEER, HSPF: 9.2, Twin BLDC Rotary Compressor, R-410A, 15 A Fuse, Inverter Drive, 27 dBA, 31 dBA, 34 dBA, Steel, Galvanized, 63 to 90 deg F, <=86 deg F, 17-5/16 in Overall Length, 35-7/16 in Overall Width, 7-13/16 in Overall Height, Additional Information: 1/4 in, 3/8 in Connection, Slim Duct Single-Zone Duct
Additional Information1/4 in, 3/8 in Connection, Slim Duct Single-Zone Duct
Amperage Rating10.9 A
BTU Rating12000 Btu/hr, 14000 Btu/hr
CFM Rating300 cfm, 353 cfm, 399 cfm
Compressor TypeTwin BLDC Rotary
Drive TypeInverter
EER Rating11.5
FinishGalvanized
Frequency Rating60 Hz
Fuse Rating15 A
HSPF Rating9.2
MaterialSteel
Number of Fan Speeds3
Overall Height7-13/16 in
Overall Length17-5/16 in
Overall Width35-7/16 in
Phase1 ph
Power Rating84 W
Refrigerant TypeR-410A
SEER Rating19
Sound Level27 dBA, 31 dBA, 34 dBA
Temperature Rating63 to 90 deg F, <=86 deg F
Voltage Rating208-230 V
The outdoor unit shall supply power to indoor unit via 14 AWG x 3 power wire
High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
Auto-restart after power loss
Soft start compressor minimizing current inrush
All heat exchangers shall be mechanically bonded aluminum fin to copper tube
The condensing unit heat exchanger salt spray test method ISO 9227 the heat exchanger showed no unusual rust or corrosion development to 500 hr
Base pan heater equipped as standard indoor fan is sirocco-type
Three-fan speed settings and auto setting
Washable filter as standard
Control wiring shall be two 16 AWG
No additional interface modules/adapters are required when connecting to Samsung central control options
The unit shall be operated via a wireless or wired remote control with DDC type signal
Dual-set temperature support when connected to MWR-WG00UN advanced wired controller or central control options
Wired or wireless controllers must be purchased separately
The compressor shall be hermetically sealed, inverter controlled BLDC rotary type
Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit