Samsung Single Zone Heat Pump Split System Indoor Unit, Duct S Series, 208 to 230 V, 26.4 A, 244 W, 60 Hz, 1 ph, 30000 to 35000 Btu/hr, 1130 cfm, 13 EER Rating, 20 SEER, 10 HSPF, Pipe Connection, Twin BLDC Rotary Compressor, R-32 Refrigerant, Inverter Drive, 41 dBA Sound Level, Steel, Finish: Galvanized, 64 to 90 deg F, 29-1/8 in Overall Length, 55-3/16 in Overall Width, 11-13/16 in Overall Height
Amperage Rating26.4 A
BTU Rating30000 to 35000 Btu/hr
CFM Rating1130 cfm
Compressor TypeTwin BLDC Rotary
Connection TypePipe
Drive TypeInverter
EER Rating13
FinishGalvanized
Frequency Rating60 Hz
HSPF Rating10
MaterialSteel
Overall Height11-13/16 in
Overall Length29-1/8 in
Overall Width55-3/16 in
Phase1 ph
Power Rating244 W
Refrigerant TypeR-32
SEER Rating20
SeriesDuct S Series
Sound Level41 dBA
Temperature Rating64 to 90 deg F
Voltage Rating208 to 230 V
The system shall provide high heating capacity at -4degF (-20degC) with heating operation down to -13degF (-25degC).
The outdoor unit shall have a base pan heater as standard for optimal defrost cycle water drainage.
The indoor unit shall have an integral condensate pump with maximum 29" lift from bottom of the unit with check valve and float switch that disables indoor in the event of condensate overflow.
The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort.
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app.
Auto-restart after power loss
Soft-start compressor minimizing current inrush
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable.
Outdoor unit: Galvanized steel with a baked-on powder coated finish for durability.
Indoor unit: Insulated, galvanized steel.
All heat exchangers shall be mechanically bonded aluminum fin to copper tube.
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire.
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit.
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection when the optional refrigerant leak detector is installed and configured (leak detector and MIM-B14U accessories are required).
Smart pressure control feature that adjusts fan speed based on ESP delivering consistent heating and cooling power
The indoor unit shall have a smart-tuning function that can provide optimized comfort by allowing the occupant to offset the fan CFM curve to increase or decrease airflow.
The indoor unit shall have automatic air volume scanning for simple setup and optimized comfort settings for the occupant
Control wiring shall be 2 X 16 AWG wire.
No additional interface modules/adapters are required when connecting to Samsung central control options.