Samsung Multi-Position Air Handler, 1.49 ton Nominal Capacity, 18000 Btu/hr Cooling Capacity, 20000 Btu/hr Heating, 18000 Btu/hr, 208-230 V, 1.5 A, 5.28 kW Wattage, 60 Hz, 1 ph, 495 to 600 cfm, Flared Connection, R-32 Refrigerant, 40 dBA Sound Level, 3/4 in Connection, 1/4 in Liquid Line, 1/2 in Suction Line, 3 Speed, Constant Torque Motor, 0.58 in-WC, Steel, Galvanized, 64 to 90 deg F Cooling, <=86 deg F Heating, 43 in H x 17-1/2 in W x 21 in D, For Use With Multi-Zone Systems
Additional InformationFor Use With Multi-Zone Systems
Amperage Rating1.5 A
BTU Rating18000 Btu/hr
CFM Rating495 to 600 cfm
Connection Size3/4 in
Connection TypeFlared
Cooling Capacity18000 Btu/hr
Dimensions43 in H x 17-1/2 in W x 21 in D
FinishGalvanized
Frequency Rating60 Hz
Heating Capacity20000 Btu/hr
Liquid Line Size1/4 in
MaterialSteel
Motor TypeConstant Torque
Nominal Capacity1.49 ton
Number of Speeds3
Phase1 ph
Pressure Rating0.58 in-WC
Refrigerant TypeR-32
Sound Level40 dBA
Suction Line Size1/2 in
Temperature Rating64 to 90 deg F Cooling, <=86 deg F Heating
Voltage Rating208-230 V
Wattage5.28 kW
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire (when accessory electric heat kits are not installed)
Insulated, galvanized steel
The heat exchanger shall be mechanically bonded aluminum fin to copper tube
Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection (MIM-B14U accessory is required)
Three fan speeds and auto setting
Control wiring shall be 2 X 16 AWG wire
The unit shall be operated via a wireless or wired remote control with DDC type signal
Dual set temperature support when connected to supported controllers
Wired or wireless controllers must be purchased separately
External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
External heat control configuration settings include outside ambient external heat lockout, outside ambient compressor lockout, and time delay options (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating (MIM-B14U accessory required when controlling heating devices other than VHK-***C electric heat kits)
External heat control functionality allows for configuration of fan operation during auxiliary heat operation, defrost, and emergency heat
Emergency heat functionality allows the system to continue controlling the external heat source even when system errors prevent the heat pump from operating
Emergency Temperature Output (ETO) function: when indoor unit is in error status or when room temperature exceeds configurable temperature level, the system outputs a signal to an external source, e.g., backup system, building management system, alert device (ex: status light, warning lamp, buzzer)