Samsung Air Handler, 13000 to 40000 Btu/hr Cooling Capacity, 10000 to 43000 Btu/hr Heating, 30000 to 34000 Btu/hr, 208 to 230 V, 14.8 A, 410 W Wattage, 60 Hz, 1 ph, Inverter Driven, Twin BLDC Rotary Compressor, 1007 cfm, Multi-Position, 13 EER Rating, 19 SEER, FNPT Connection, R-32 Refrigerant, 41 dBA Sound Level, 3/4 in Connection, 3 Speed, Steel, Finish: Galvanized, 64 to 90 deg F, 48-3/4 in H x 23-1/4 in W x 21 in D
Amperage Rating14.8 A
BTU Rating30000 to 34000 Btu/hr
CFM Rating1007 cfm
Compressor TypeInverter Driven, Twin BLDC Rotary
ConfigurationMulti-Position
Connection Size3/4 in
Connection TypeFNPT
Cooling Capacity13000 to 40000 Btu/hr
Dimensions48-3/4 in H x 23-1/4 in W x 21 in D
EER Rating13
FinishGalvanized
Frequency Rating60 Hz
Heating Capacity10000 to 43000 Btu/hr
MaterialSteel
Number of Speeds3
Phase1 ph
Refrigerant TypeR-32
SEER Rating19
Sound Level41 dBA
Temperature Rating64 to 90 deg F
Voltage Rating208 to 230 V
Wattage410 W
The system shall provide high heating capacity at -4degF (-20degC) with heating operation down to -13degF (-25degC).
The outdoor unit shall have a base pan heater as standard for optimal defrost cycle water drainage.
The system shall feature comfort humidity control. Utilizing an integral humidity sensor, the system optimizes the indoor unit coil temperature according to the dew point, maximizing energy savings while still providing space dehumidification and occupant comfort.
The system shall have a built-in Wi-Fi adapter as standard to allow control and monitoring using the Samsung SmartThings app.
Auto-restart after power loss
Soft-start compressor minimizing current inrush
The outdoor unit shall provide 208/230V power to the indoor unit via 14 AWG X 3 interconnect power cable.
Outdoor unit: Galvanized steel with a baked-on powder coated finish for durability.
Indoor unit: Insulated, galvanized steel.
All heat exchangers shall be mechanically bonded aluminum fin to copper tube.
The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire (when accessory electric heat kits are not installed).
The system shall utilize low-GWP R-32 refrigerant
Refrigerant flow shall be controlled by electronic an expansion valve at the outdoor unit
The system shall include an R32 alarm output plug on the indoor unit and outdoor unit for notification of R32 leak detection (MIM-B14U accessory is required).
Three fan speeds and auto setting
Control wiring shall be 2 X 16 AWG wire.
No additional interface modules/adapters are required when connecting to Samsung central control options.
The unit shall be operated via a wireless or wired remote control with DDC type signal.
Dual set temperature support when connected to supported controllers.
Wired or wireless controllers must be purchased separately. External Heat Control (not required for use with VHK-***C Electric Heat Kits)